QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
QuickTie Cable
QuickTie™ cables are used to resist uplift loads from the roof system, shear at the bottom plate and overturning forces at the ends of shear walls. When QuickTie™ cables are used, it is possible to omit all straps and construction hardware between the double top plates on the uppermost floor to the sole or sill plate on the lowest floor. Hurricane clips attaching the double top plate to the trusses must remain, however. A single QuickTie™ installed between the double top plate of the uppermost floor and the foundation serves adequately as a hold down for any shear wall. It replaces one holddown on the lowest floor and straps between floors at the second floor and third floor.
Corner Hip Plate
Corner Hip Plates (CHP) are used to secure trusses or rafters to double top plates, effectively resisting uplift forces
CHP1.81 to CHP4
MiTek HHCP2MiTek HHCP2-TZMiTek HHCP4-TZSimpson HCP1.81+3 more
Form Tie
Form Tie (FT8) and Form Wedge (FTW) anchors provide easy installation for the foundation contractor or framer. They can be used in either stem walls or slabs. They are easily attached to the form prior to placement of concrete.
FT6 to FT8
Girder Tie-Down
The QuickTie™ Girder Connectors (QGC & QGCW) are used for girder truss connections where uplift load requirements are high.
Uplift 8,715 lb
MiTek MUGT15Simpson MGTSimpson VGT
Girder Tie-Down
The PHGT series connectors, also known as Post-Install Girder Tie Downs, offer an effective solution for securing multi-ply girder trusses and facilitating the transfer of lateral wind loads to supporting wood and masonry walls.
Uplift 3,355 – 4,185 lbPHHGT3 to PHHGT4
MiTek LUGT3MiTek LUGT4Simpson LGT3-SDS2.5Simpson LGT4-SDS3
Girder Tie-Down
The PHGT series connectors, also known as Post-Install Girder Tie Downs, offer an effective solution for securing multi-ply girder trusses and facilitating the transfer of lateral wind loads to supporting wood and masonry walls.
Uplift 2,435 lb
MiTek LUGT2Simpson LGT2
Hanger
The truss hip/jack hanger is designed to securely attach the hip and jack trusses to the girder truss. Its wide seat design allows for the use of both 2-ply and a combination of 1-ply and 2-ply hip and jack trusses.
Load 2,255 – 2,590 lbTHJH26 to THJH26-W
MiTek HJC26MiTek HJC26SK60Simpson THJA26Simpson THJU26+1 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 4,340 – 10,500 lbUHD26-3 to UHD6814
MiTek THD46MiTek THD610-TZMiTek THD612MiTek THD612-TZ+77 more
Hanger
The Top Flange Heavy (TFHD) U-Hanger Series are top-mounted joist hangers that resist gravity and wind uplift loads in single- or multi-ply joist assemblies for light-frame construction.
TFHD26 to TFHD614
MiTek HD26-2MiTek HDO210MiTek HDO210-2MiTek HDO212+29 more
Hanger
12ga MPH3.50-18OSL (Offset Saddle Left) Top Mount Welded Hanger
MPH3.50-18OSL to MPH3518
MiTek MPH3518MiTek MPH3518OSLMiTek MPH3518OSRMiTek MPH410-OSR+10 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 2,830 – 5,705 lbUHH46 to UHH210-2
MiTek THD210-2MiTek THD210-2TZMiTek THD210-3MiTek THD210-4+28 more
Hanger
Top Flange U-Hanger Series are top mount joist hangers used to resist gravity loads and uplift loads due to wind in single or multi-ply joist assembly in light-frame construction.
Load 1,535 lbTFH210 to TFH181-16
MiTek HL210MiTek HL212MiTek HL214Simpson JB210A+2 more
Hanger
The UMSR/L and UHSR/L series are face mount U-hangers, skewed at a 45-degree angle (R - Right or L- Left), used for connecting skewed joist/beam to the headers or trusses.
Load 1,785 – 5,575 lbUHSL28-2 to UHSR214-2
MiTek SKHH210L-2MiTek SKHH210L-2TZMiTek SKHH210R-2MiTek SKHH210R-2TZ+30 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 1,445 – 2,320 lbUM46R to UM210R
MiTek SUH210RMiTek SUH26RMiTek SUH28RMiTek SUH410R+5 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 3,050 – 6,740 lbUMH26 to UMH210
MiTek HUS210MiTek HUS210-TZMiTek HUS26MiTek HUS26-TZ+8 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 1,445 – 2,320 lbUM26-3 to UM310
MiTek SUH210-2MiTek SUH210-3MiTek SUH26MiTek SUH26-2+16 more
Hanger
16ga 2x6 (1-ply) U-Hanger
UMTU26 to UMTU210-2
MiTek THD210MiTek THD210-2MiTek THD26MiTek THD26-2+8 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 2,190 – 2,265 lbULP410 to ULP412
MiTek JUS410MiTek JUS410-TZMiTek JUS412MiTek SUH410+4 more
Hanger
The ULPSSH is a field-adjustable hanger engineered to
support trusses or rafters with varying skew and slope
configurations when connecting to beams or other
structural members.
Load 680 – 1,185 lbULPSSH26 to ULPSSH210
MiTek LSSH15-TZMiTek LSSH179MiTek LSSH179-TZMiTek LSSH210+11 more
Hanger
Top Flange U-Hanger Series are top mount joist hangers used to resist gravity loads and uplift loads due to wind in single or multi-ply joist assembly in light-frame construction.
Load 1,245 lbTFLP26 to TFLP28
MiTek HL26MiTek HL28MiTek KLB26MiTek KLB28+4 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 1,215 – 2,175 lbUL26-3 to UL212
MiTek JL210MiTek JL26MiTek JL28MiTek JUS210+32 more
Hanger
3ga/7ga 5.625x20, TF Offset Left, Top Mount Welded Hanger
TFHWH5.62-20OSL to TFHWH3.56-21
Simpson HWPH5.62_H=20_OSLSimpson HWPH5.62_H=20_OSR
Hanger
7ga HGUM5.50 (H = 18") Heavy Face-Mount Girder Hanger IFR w/ masonry and wood screws
HGUM5.50-18IFR to HGUM5.50-24IFR
MiTek HGUM550_H=18IFRMiTek HGUM550_H=18IFR45SMiTek HGUM550_H=24_IFRSimpson HGUM5.50-SDSIFR+1 more
Hanger
3ga/7ga 5-5/8" x 24" High capacity Top flange Hanger
KEG9-24 to KEGS562-24
MiTek KEG9_H24Simpson EG9Simpson EGQ5.37-SDS3_H=16Simpson EGQ5.62-SDS3
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 705 – 2,175 lbULU24 to ULU210-2
MiTek JL24MiTek JL26MiTek JL28MiTek JUS210-2+20 more
Hanger
Top Flange Header Beam Hangers (TFHBH) are heavy header-to-beam connectors used for supporting and transferring high loads from the LVL, LSL and PSL beams to the header.
Load 10,545 lbTFHBH3595 to TFHBH3520
MiTek 11.87 Simpson®MiTek HLBH3512MiTek HLBH3514MiTek HLBH3516+16 more
Hanger
TSH (Truss Strap Hangers) are long strap hangers designed for both face mount and top mount applications.
Load 2,345 – 5,190 lbTSH29 to TSH426-2
MiTek MSH213MiTek MSH218MiTek MSH218-2MiTek MSH222-2+20 more
Hanger
TSH (Truss Strap Hangers) are long strap hangers
designed for both face mount and top mount applications.
TSH-IF418 to TSH-IF426-2
MiTek MSH418IFMiTek MSH422-2IFMiTek MSH426IFSimpson THAC418+3 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 865 – 3,170 lbUH26-3 to UH614SMC
MiTek HD210MiTek HD210-2MiTek HD210-2IFMiTek HD210-2IFTZ+90 more
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
UH-IF28-3SMC to UH-IF614SMC
MiTek HDQ210-3IFSimpson HUC210-3
Hanger
U-Hanger and Inverted Flange (IF) U-Hanger Series are face mount joist items used to resist gravity loads and uplift loads due to wind in one-, two- and three-ply joist assemblies in light-frame wood construction. These are used as wood framing connectors in accordance with IBC Section 2304.10.4 and IRC Section R301.1.3.
Load 1,230 – 2,190 lbULP26R to ULP412R
Simpson LU210R-18Simpson LU26R-18Simpson LU28R-18Simpson LUS210R-18+1 more
Hanger
The UMSR/L and UHSR/L series are face mount U-hangers, skewed at a 45-degree angle (R - Right or L- Left), used for connecting skewed joist/beam to the headers or trusses.
Load 625 – 4,225 lbUMSL28 to UMSR414
MiTek SKH210LMiTek SKH210L-2MiTek SKH210L-2TZMiTek SKH210L-TZ+58 more
Hurricane Anchor
Hurricane Anchors/Clips (HA4, HA6, HA8 & HA10) add increased resistance to wind uplift. HA’s reduces toe-nailing, utilizing correctly located nail holes for fast, easy and strong attachment of rafters and trusses to plates and studs.
Uplift 662 – 1,350 lbHA4 to HA10R
MiTek RT16-2MiTek RT16-2TZMiTek RT16AMiTek RT16A-TZ+25 more
Hurricane Gusset Angle
Hurricane Gusset Angles (HGA/HGAM) are 90-degree framing angles used to connect truss/rafter joists to the top plate of wood framing walls or to the top of concrete filled CMU walls. The HGAKT and HGAMKT includes HGA framing angle and wood screws for wood framing applications and HGA framing angle, wood screws and concrete screws for concrete/CMU applications, respectively.
Uplift 815 – 1,085 lbHGA to HGAMKT
MiTek HGA10KTMiTek HGAM10KTSimpson HGA10KTSimpson HGAM10KTA
Jack Truss Connector
JTCs, or Jack Truss Connectors, are designed to be easily skewable, allowing them to be field-bent to various angles for a wide range of applications.
Uplift 400 – 815 lbJTC37-3Z to JTC57-3Z
MiTek SNP3Simpson TJC37Simpson TJC57
Nail Protection Plate
The NPP Series protects electrical wires and plumbing lines from damage caused by nails, screws, and other piercing hazards. Built-in prongs provide fast, secure instal
NPP1 to NPP516
MiTek ICPL516-TZMiTek ICPL58-TZMiTek KNS1MiTek PL4+4 more
Plywood Clip
20ga 1/2" Steel Plywood Clips (FCO/250)
PC12 to PC1932
MiTek PC12MiTek PC1532MiTek PC1932MiTek PC34+14 more
Post Cap
PCS and PCES are post caps and end post caps used for post-to-beam connection applications.
Uplift 1,645 – 1,955 lbPCES44 to PCES66
MiTek PBES44MiTek PBES44-TZMiTek PBES66MiTek PBES66-TZ+2 more
Post Cap
3ga 7.1x6x3.2 ECCSLL End Column Cap,3.2x Left Leg Beam(H2=H1,Beamsflushatbottom),w/Scrws(FCO/1) (Ref: Simpson® / KECCQLL71-6-3.2 MiTek®)
MiTek KECCQLL71-6-3.2Simpson ECCLLQ71-6-32 SDS
Post Cap
3ga 7.1x6x3.2 ECCSLR End Column Cap,3.2x Right Leg Beam(H2=H1,Beamsflushatbottom),w/Scrws(FCO/1) (Ref: ECCLRQ71-6-32 SDS Simpson® / KECCQLR71-6-3.2 MiTek®)
MiTek KECCQLR71-6-3.2Simpson ECCLRQ71-6-32 SDS
Post Cap
Welded Column Caps (CCS) and End Column Caps (ECCS) are heavy post to beam connectors that uses QuickTie Structural Wood Screws for higher load rating.
Uplift 7,420 lbCCS4-71 to CCS525-8
MiTek KCCQ106MiTek KCCQ325-4MiTek KCCQ325-6MiTek KCCQ4-71+52 more