3ga 6.12x6 ECCS61-6 End Column Cap with Screws (FCO/1)
Welded Column Caps (CCS) and End Column Caps (ECCS) are heavy post to beam connectors that uses QuickTie Structural Wood Screws for higher load rating.
| Name ▲ | QuickTie Allowable Loads | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Reference No. | Dimensions | Fasteners | Southern Yellow Pine | Douglas Fir | |||||||||||||
| Simpson® | Mitek® | W1 | W2 | H1 | L1 | L2 | Post | Beam | Uplift(1.6) ⇅ | F1(1.6) ⇅ | F2(1.6) ⇅ | Uplift(1.6) ⇅ | F1(1.6) ⇅ | F2(1.6) ⇅ | |||
| Qty | Size | Qty | Size | ||||||||||||||
| EPCM44 | - | EPCM44 | 3 9⁄16 | 3 9⁄16 | 3 9⁄16 | 2 7⁄16 | 7 1⁄4 | 8 | 16d | 8 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM44-16 | - | EPCM4416EPCM4416-TZ | 3 9⁄16 | 3 9⁄16 | 3 9⁄16 | 2 7⁄16 | 7 1⁄4 | 8 | 16d | 8 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM46 | - | EPCM46 | 3 9⁄16 | 5 9⁄16 | 3 9⁄16 | 2 7⁄16 | 9 1⁄4 | 9 | 16d | 9 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM46-16 | - | EPCM4616-TZEPCM4616 | 3 9⁄16 | 5 9⁄16 | 3 9⁄16 | 2 7⁄16 | 9 1⁄4 | 9 | 16d | 9 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM48 | - | EPCM48 | 3 9⁄16 | 7 9⁄16 | 3 9⁄16 | 2 7⁄16 | 11 1⁄4 | 10 | 16d | 10 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM48-16 | - | EPCM4816 | 3 9⁄16 | 7 9⁄16 | 3 9⁄16 | 2 7⁄16 | 11 1⁄4 | 10 | 16d | 10 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM64 | - | EPCM64 | 5 1⁄2 | 3 9⁄16 | 3 1⁄2 | 3 13⁄16 | 7 1⁄4 | 11 | 16d | 11 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM64-16 | - | EPCM6416 | 5 1⁄2 | 3 9⁄16 | 3 1⁄2 | 3 13⁄16 | 7 1⁄4 | 11 | 16d | 11 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM66 | - | EPCM66EPCM66-TZ | 5 1⁄2 | 5 9⁄16 | 3 1⁄2 | 3 13⁄16 | 9 1⁄4 | 12 | 16d | 12 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM66-16 | - | EPCM6616-TZEPCM6616 | 5 1⁄2 | 5 9⁄16 | 3 1⁄2 | 3 13⁄16 | 9 1⁄4 | 12 | 16d | 12 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM68 | - | EPCM68 | 5 1⁄2 | 7 9⁄16 | 3 1⁄2 | 3 13⁄16 | 11 1⁄4 | 13 | 16d | 13 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM68-16 | - | EPCM6816 | 5 1⁄2 | 7 9⁄16 | 3 1⁄2 | 3 13⁄16 | 11 1⁄4 | 13 | 16d | 13 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM77 | - | EPCM77 | 7 1⁄8 | 7 1⁄8 | 3 11⁄16 | 5 5⁄8 | 10 13⁄16 | 14 | 16d | 14 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM84 | - | EPCM84 | 7 1⁄2 | 3 9⁄16 | 3 1⁄2 | 5 5⁄8 | 7 1⁄4 | 15 | 16d | 15 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM84-16 | - | EPCM8416 | 7 1⁄2 | 3 9⁄16 | 3 1⁄2 | 5 5⁄8 | 7 1⁄4 | 14 | 16d | 14 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM86 | - | EPCM86 | 7 1⁄2 | 5 9⁄16 | 3 1⁄2 | 5 5⁄8 | 9 1⁄4 | 16 | 16d | 16 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM86-16 | - | EPCM8616 | 7 1⁄2 | 5 9⁄16 | 3 1⁄2 | 5 5⁄8 | 9 1⁄4 | 15 | 16d | 15 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
| EPCM88 | EPC88 | EPCM88 | 7 1⁄2 | 7 9⁄16 | 3 1⁄2 | 5 5⁄8 | 11 1⁄8 | 17 | 16d | 17 | 16d | 2,120 | 2,050 | 1,955 | 2,085 | 1,855 | 1,795 |
| EPCM88-16 | - | EPCM8816 | 7 1⁄2 | 7 9⁄16 | 3 1⁄2 | 5 5⁄8 | 11 1⁄4 | 16 | 16d | 16 | 16d | 1,875 | 1,815 | 1,730 | 1,845 | 1,640 | 1,590 |
Use all specified fasteners to achieve the values shown. Reference numbers are for comparison only and do not imply identical performance.
Welded Column Caps (CCS) and End Column Caps (ECCS) are heavy post to beam connectors that uses QuickTie Structural Wood Screws for higher load rating.
3ga 7.1x6x3.2 ECCSLL End Column Cap,3.2x Left Leg Beam(H2=H1,Beamsflushatbottom),w/Scrws(FCO/1) (Ref: Simpson® / KECCQLL71-6-3.2 MiTek®)
3ga 7.1x6x3.2 ECCSLR End Column Cap,3.2x Right Leg Beam(H2=H1,Beamsflushatbottom),w/Scrws(FCO/1) (Ref: ECCLRQ71-6-32 SDS Simpson® / KECCQLR71-6-3.2 MiTek®)
Welded Column Caps (CCS) and End Column Caps (ECCS) are heavy post to beam connectors that uses QuickTie Structural Wood Screws for higher load rating.
Tell me what you're building and I'll find the QuickTie connector for it. Sizes, loads, wood species, coating or a competitor part number all help.